Load Data

  • Earthquake load is excluded in the standard foundation load data. If it is impossible to get the precise earthquake load, set the default value of frequently and rarely occurred earthquake in the template as 1. In the Greenwich user interface, input seismic oscillation parameters of the project and select base shear method to calculate the earthquake load.
  • For fatigue load, input Inverse SN Slope as load data for 3-12.
  • It is not needed to input Mxy for average load under normal working condition at rated wind speed.
  • Adopt default values for Markov matrix.
  • Under normal condition and extreme condition, maximum bending moment Mxy is located at the second row from the bottom. If the maximum Mxy is not at the second row from the bottom, copy the row with the maximum values to that row manually.